Logo
Login Sign Up
Current Revision

ASTM C1629/C1629M-24

Standard Classification for Abuse-Resistant Nondecorated Interior Gypsum Panel Products and Fiber-Reinforced Cement Panels
Best Price Guarantee
Instant
2-5 Days
SAVE 10%

$76.00

$76.00

$136.80

$91.00

$91.00

$163.80



Sub Total (1 Item(s))

$ 0.00

Estimated Shipping

$ 0.00

Total (Pre-Tax)

$ 0.00


View in Library
or
ASTM International Logo

ASTM C1629/C1629M-24

Standard Classification for Abuse-Resistant Nondecorated Interior Gypsum Panel Products and Fiber-Reinforced Cement Panels

PUBLISH DATE 2024
PAGES 16
ASTM C1629/C1629M-24

1.1 This standard establishes classifications of abuse resistance based on the abrasion resistance and impact resistance performance of nondecorated interior gypsum panel products and fiber-reinforced cement panels (abuse resistant wall panels).

1.1.1 This standard is a method of classifying gypsum panel product performance and is not intended to classify systems for abuse resistance.

1.2 The values stated in inch-pound and SI (metric) units are to be regarded separately as standard. Within the text, the SI units are shown in brackets. The values stated in each system shall be used independent of the other. Values from the two systems shall not be combined.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

1.1 This standard establishes classifications of abuse resistance based on the abrasion resistance and impact resistance performance of nondecorated interior gypsum panel products and fiber-reinforced cement panels (abuse resistant wall panels).

1.1.1 This standard is a method of classifying gypsum panel product performance and is not intended to classify systems for abuse resistance.

1.2 The values stated in inch-pound and SI (metric) units are to be regarded separately as standard. Within the text, the SI units are shown in brackets. The values stated in each system shall be used independent of the other. Values from the two systems shall not be combined.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

4.1 Each abuse/impact property of abuse resistant wall panels is divided into three classification levels.

The three levels of classification are: Level I, Level II, and Level III, with Level I representing the lowest rating for any given property.

The test methods specified are utilized to establish the abuse-resistance classification of an abuse resistant wall panel.

Each classification level requires a minimum overall specified performance.

Any classified abuse resistant wall panel can be used at a classification level which is rated lower than the highest level qualified.

SDO ASTM: ASTM International
Document Number C1629
Publication Date Dec. 1, 2024
Language en - English
Page Count 16
Revision Level 24
Supercedes
Committee C11.01
Loading...

Failed to load document history.

Publish Date Document Id Type View