Standard Practice for The Separation of Lanthanide Elements from Uranium Matrices Using High Pressure Ion Chromatography (HPIC) for Isotopic Analyses by Inductively Coupled Plasma Mass Spectrometry (ICP-MS)

PUBLISH DATE 2024
PAGES 8
ASTM C1845-24

1.1 This practice provides instructions for the rapid separation of lanthanide elements using high pressure ion chromatography (HPIC) from dissolved uranium materials such as: nuclear fuels, uranium ores, hydrolyzed UF6, and depleted, natural, or enriched oxides/powders, or metals.

When optimized, this technique will produce purified elemental fractions of the lanthanide elements isolated from the bulk uranium matrix allowing for isotopic assay using inductively coupled plasma mass spectrometry (ICP-MS).

1.2 This practice is most applicable for analyte concentrations of nanograms per gram uranium or higher.

For ICP-MS detection and measurement of analyte concentrations lower than this, it would be necessary to perform additional pre-cleanup or concentration techniques, or both, which are not addressed in this practice.

1.3 When combined with isotope dilution, this practice can also be used for improved precision assays of the lanthanide elements using the principle of isotope dilution mass spectrometry (IDMS).

1.4 The values stated in SI units are to be regarded as standard.

Additionally, the non-SI units of molarity and centimeters of mercury are to be regarded as standard.

No other units of measurement are included in this practice.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use.

It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

Some specific hazards statements are given in Section 9 on Hazards.

1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

1.1 This practice provides instructions for the rapid separation of lanthanide elements using high pressure ion chromatography (HPIC) from dissolved uranium materials such as: nuclear fuels, uranium ores, hydrolyzed UF6, and depleted, natural, or enriched oxides/powders, or metals. When optimized, this technique will produce purified elemental fractions of the lanthanide elements isolated from the bulk uranium matrix allowing for isotopic assay using inductively coupled plasma mass spectrometry (ICP-MS).

1.2 This practice is most applicable for analyte concentrations of nanograms per gram uranium or higher. For ICP-MS detection and measurement of analyte concentrations lower than this, it would be necessary to perform additional pre-cleanup or concentration techniques, or both, which are not addressed in this practice.

1.3 When combined with isotope dilution, this practice can also be used for improved precision assays of the lanthanide elements using the principle of isotope dilution mass spectrometry (IDMS).

1.4 The values stated in SI units are to be regarded as standard. Additionally, the non-SI units of molarity and centimeters of mercury are to be regarded as standard. No other units of measurement are included in this practice.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Some specific hazards statements are given in Section 9 on Hazards.

1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

5.1 The measurement of isotopic distributions for the lanthanide series elements is of important to all phases of the nuclear fuels cycle.

Examples include the purification of the Nd isotopes from Ce and Sm isotopes for the determination of atom percent fission through the production of 148Nd in irradiated nuclear fuels using Practice C1769, determination of rare earth content and isotopic distribution in Uranium Ore Concentrates (UOC) for source term and production of lanthanide fission products in irradiated nuclear fuels for determination of performance, improvements of depletion codes, and analysis of burnup indicators.4

SDO ASTM: ASTM International
Document Number C1845
Publication Date Dec. 1, 2024
Language en - English