ASTM D4947-05

Current Revision
Standard Test Method for Chlordane and Heptachlor Residues in Indoor Air

Best Price Guarantee Mar 1, 2005 English 8 Pages

Sub Total (1 Item(s)) $ 0.00
Estimated Shipping $ 0.00
Total (Pre-Tax) $ 0.00

You own the digital copy of this edition

View in Library
or
ASTM D4947-05 PDF Preview
ASTM D4947-05

1.1 This test method covers the sampling and analysis of indoor atmospheres for residues of chlordane and heptachlor.

1.2 This test method is based upon the collection of chlordane and heptachlor from air onto polyurethane foam (PUF) and analysis by gas chromatography coupled with electron capture detection.

1.3 This test method is applicable to concentrations of chlordane varying from 0.1 to 100 g/m3 and heptachlor varying from 0.01 to 80.0 g/m3 with sampling periods to collect at least 0.25 m3 of air. Detection limits will depend upon the conditions of the gas chromatography (GC) and the length of the sampling period.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

1.1 This test method covers the sampling and analysis of indoor atmospheres for residues of chlordane and heptachlor.

1.2 This test method is based upon the collection of chlordane and heptachlor from air onto polyurethane foam (PUF) and analysis by gas chromatography coupled with electron capture detection.

1.3 This test method is applicable to concentrations of chlordane varying from 0.1 to 100 g/m3 and heptachlor varying from 0.01 to 80.0 g/m3 with sampling periods to collect at least 0.25 m3 of air. Detection limits will depend upon the conditions of the gas chromatography (GC) and the length of the sampling period.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

This test method is intended to be used primarily for non-occupational exposure monitoring in domiciles, public access buildings, and offices.

Chlordane has been used widely as a general insecticide for crops (for example, cotton) and as a termiticide. Heptachlor is a major component of technical chlordane and an insecticide in its own right.

Although their use in the United States was discontinued in 1988, residues of the chemicals may remain in indoor air for many years after application.