1.1 This test method covers an analytical procedure for determining the transmissivity of a confined aquifer. This test method is used to analyze data from the recovery of water levels following pumping or injection of water to or from a control well at a constant rate.
1.2 The analytical procedure given in this test method, along with several others, is used in conjunction with the field procedure in Test Method D4050. Guide D4043 provides information for determining hydraulic properties.
1.3 Limitations— The valid use of the Theis recovery method is limited to determination of transmissivities for aquifers in hydrogeologic settings reasonably corresponding to the assumptions of the Theis theory (see 5.2).
1.4 Units— The values stated in either SI Units or inch-pound units are to be regarded separately as standard. The values in each system may not be exact equivalents; therefore each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. Reporting of test results in units other than SI shall not be regarded as nonconformance with this test method.
1.5 All observed and calculated values shall conform to the guidelines for significant digits and rounding established in Practice D6026. All observed and calculated values shall conform to the guidelines for significant digits and rounding established in Practice D6026, unless otherwise superseded by this standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
1.1 This test method covers an analytical procedure for determining the transmissivity of a confined aquifer. This test method is used to analyze data from the recovery of water levels following pumping or injection of water to or from a control well at a constant rate.
1.2 The analytical procedure given in this test method, along with several others, is used in conjunction with the field procedure in Test Method D4050. Guide D4043 provides information for determining hydraulic properties.
1.3 Limitations— The valid use of the Theis recovery method is limited to determination of transmissivities for aquifers in hydrogeologic settings reasonably corresponding to the assumptions of the Theis theory (see 5.2).
1.4 Units— The values stated in either SI Units or inch-pound units are to be regarded separately as standard. The values in each system may not be exact equivalents; therefore each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. Reporting of test results in units other than SI shall not be regarded as nonconformance with this test method.
1.5 All observed and calculated values shall conform to the guidelines for significant digits and rounding established in Practice D6026. All observed and calculated values shall conform to the guidelines for significant digits and rounding established in Practice D6026, unless otherwise superseded by this standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
5.1 This test method is useful for analyzing data on the recovery of water levels following pumping or injection of water to or from a control well at a constant rate. The analytical procedure given in this test method along with several others is used in conjunction with the field procedure in Test Method D4050.
5.2 Assumptions:
5.3 Implications of Assumptions:
Note 1: The quality of the result produced by this standard is dependent on the competence of the personnel performing it, and the suitability of the equipment and facilities used. Agencies that meet the criteria of Practice D3740 are generally considered capable of competent and objective testing/sampling/inspection. Users of this standard are cautioned that compliance with Practice D3740 does not in itself assure reliable results. Reliable results depend on many factors; Practice D3740 provides a means of evaluating some of those factors.