Standard Test Method for Load Controlled Cyclic Triaxial Response of Soil
1.1 This test method describes performing load-controlled cyclic undrained triaxial tests to evaluate the cyclic response of saturated soils in either intact or reconstituted states.
1.2 The cyclic response of the soil is evaluated relative to a number of factors, including the magnitude and offset of applied cyclic stress, the development of cyclic and average axial strains, the number of cycles of stress application, the development of excess pore-water pressure, state of effective stress, and the soil fabric. A comprehensive review of factors affecting cyclic triaxial test results is contained in the literature (1).2
1.3 The cyclic triaxial tests described in this standard are conducted under undrained conditions to simulate essentially undrained field conditions during an earthquake or other cyclic loading.
1.4 Cyclic triaxial tests are destructive. Failure may be defined based on the number of stress cycles required to reach a limiting axial strain or 100 % pore pressure ratio. See Section 3 for Terminology.
1.5 This test method is generally applicable for testing coarser-grained, free-draining soils of relatively high permeability. When testing well-graded materials, silts, or clays, pore-water pressures monitored at the specimen ends may not represent pore-water pressure values throughout the specimen. However, this test method may be followed when testing most soil types if care is taken to ensure that problem soils receive special consideration when tested and when test results are evaluated.
1.6 Further applications of the cyclic triaxial test and the interpretation of its results in determining soil’s cyclic behavior and classifying them is the subject of ongoing research.
1.7 Limitations—There are certain limitations inherent in using cyclic triaxial tests to simulate the stress and strain conditions of a soil element in the field during an earthquake.
1.8 Units—The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. Reporting of test results in units other than SI shall not be regarded as nonconformance with this standard.
1.9 All observed and calculated values shall conform to the guidelines for significant digits and rounding established in Practice D6026 unless superseded by this test method.
1.9.1 The procedures used to specify how data are collected/recorded or calculated in the standard are regarded as the industry standard. In addition, they are representative of the significant digits that generally should be retained. The procedures used do not consider material variation, the purpose for obtaining the data, special purpose studies, or any considerations for the user’s objectives; and it is common practice to increase or reduce significant digits of reported data to be commensurate with these considerations. It is beyond the scope of this standard to consider significant digits used in analysis methods for engineering design.
1.10 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.11 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
1.1 This test method describes performing load-controlled cyclic undrained triaxial tests to evaluate the cyclic response of saturated soils in either intact or reconstituted states.
1.2 The cyclic response of the soil is evaluated relative to a number of factors, including the magnitude and offset of applied cyclic stress, the development of cyclic and average axial strains, the number of cycles of stress application, the development of excess pore-water pressure, state of effective stress, and the soil fabric. A comprehensive review of factors affecting cyclic triaxial test results is contained in the literature (1).2
1.3 The cyclic triaxial tests described in this standard are conducted under undrained conditions to simulate essentially undrained field conditions during an earthquake or other cyclic loading.
1.4 Cyclic triaxial tests are destructive. Failure may be defined based on the number of stress cycles required to reach a limiting axial strain or 100 % pore pressure ratio. See Section 3 for Terminology.
1.5 This test method is generally applicable for testing coarser-grained, free-draining soils of relatively high permeability. When testing well-graded materials, silts, or clays, pore-water pressures monitored at the specimen ends may not represent pore-water pressure values throughout the specimen. However, this test method may be followed when testing most soil types if care is taken to ensure that problem soils receive special consideration when tested and when test results are evaluated.
1.6 Further applications of the cyclic triaxial test and the interpretation of its results in determining soil’s cyclic behavior and classifying them is the subject of ongoing research.
1.7 Limitations—There are certain limitations inherent in using cyclic triaxial tests to simulate the stress and strain conditions of a soil element in the field during an earthquake.
1.8 Units—The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. Reporting of test results in units other than SI shall not be regarded as nonconformance with this standard.
1.9 All observed and calculated values shall conform to the guidelines for significant digits and rounding established in Practice D6026 unless superseded by this test method.
1.9.1 The procedures used to specify how data are collected/recorded or calculated in the standard are regarded as the industry standard. In addition, they are representative of the significant digits that generally should be retained. The procedures used do not consider material variation, the purpose for obtaining the data, special purpose studies, or any considerations for the user’s objectives; and it is common practice to increase or reduce significant digits of reported data to be commensurate with these considerations. It is beyond the scope of this standard to consider significant digits used in analysis methods for engineering design.
1.10 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.11 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
5.1 Cyclic triaxial test results are used for evaluating the ability of soil to resist the shear stresses induced in a soil mass due to earthquakes or other cyclic loadings.
5.1.1 Cyclic triaxial tests may be performed at different values of effective confining pressure on isotropically or anisotropically consolidated specimens to provide data required for estimating the cyclic response of the soil.
5.1.2 Cyclic triaxial tests may be performed at a single effective confining pressure, usually equal to 100 kPa [14.5 lbf/in.2], or alternate pressures to compare cyclic response results for a particular soil type with that of other soils (2).
5.2 The cyclic triaxial test is a commonly used technique for determining cyclic soil response.
5.3 Cyclic response depends upon many factors, including density, effective confining pressure, applied cyclic stress, stress history, soil fabric, age of soil deposit, specimen reconstitution method, and the frequency, uniformity, and shape of the cyclic waveform. Thus, close attention must be given to testing details and equipment.
Note 1: The quality of the result produced by this standard is dependent on the competence of the personnel performing it and the suitability of the equipment and facility used. Agencies that meet the criteria of Practice D3740 are generally considered capable of competent and objective testing/sampling/inspection. Reliable results depend on many factors; Practice D3740 provides a means of evaluating some, but not all, of those factors.
Failed to load document history.
| Publish Date | Document Id | Type | View |
|---|