Standard Test Methods for Determination of Maximum Dry Unit Weight of Granular Soils Using a Vibrating Hammer
1.1 These test methods cover the determination of the **maximum dry unit weight** of granular soils. A vibrating hammer is used to impart a surcharge and compactive effort to the soil specimen. Further, an optional calculation is presented to determine the approximate *water content range* for effective compaction of granular soils based on the measured maximum dry density and specific gravity.
1.2 These test methods apply to primarily *granular, free-draining soils* for which impact compaction does not yield a clear optimum water content. Specifically, these test methods apply to soils:
1.3 Further, due to limitations of the testing equipment, and the available oversize correction procedures these test methods apply to soils in which:
1.4 These test methods will typically produce a *higher maximum dry unit weight* for the soils specified in 1.2.1 and 1.2.2 than that obtained by impact compaction in which a well-defined moisture-density relationship is not apparent. However, for some soils containing more than 15 % fines, the use of impact compaction (Test Methods D698 or D1557) may be useful in evaluating what is an appropriate maximum index unit weight.
1.5 Four alternative test methods are provided, with the variation being in *saturated versus dry specimens* and mold size. The method used shall be as indicated in the specification for the material being tested. If no method is specified, the choice is typically based on the maximum particle size of the material.
Note 1: Results have been found to vary slightly when a material is tested at the same compaction effort in different size molds.
1.6 If the test specimen contains more than 5 % by mass of oversize material (coarse fraction) and the material will not be included in the test, corrections must be made to the unit weight and water content results from the laboratory test or to the appropriate field in-place density test results using Practice D4718/D4718M.
Note 2: Methods 1A and 2A (with the correction procedure of Practice D4718/D4718M, if appropriate), have been shown to provide consistent results with Methods 1B and 2B for materials with 30 % or less, by dry mass retained on the 3/4-in. (19-mm) sieve. Therefore, for ease of operations, it is recommended to use Method 1A or 2A, unless Method 1B or 2B is required due to soil gradations having in excess of 30 %, by dry mass, retained on the 3/4-in. (19-mm) sieve.
1.7 This test method may cause *degradation* (particle breakdown) of the soil. When degradation occurs, typically there is an increase in the maximum unit weight obtained, and comparable test results may not be obtained when different size molds are used to test a given soil. For soils where degradation is suspected, a sieve analysis of the specimen can be performed before and after the compaction test as a tool to determine the amount of degradation.
1.8 Units—The values stated in inch-pound units are to be regarded as standard. The SI units given in parentheses are mathematical conversions, which are provided for information purposes only and are not considered standard. Reporting of test results in units other than inch-pound units shall not be regarded as nonconformance with this test method.
5.1 For many cohesionless, free-draining soils, the in place dry unit weight as a percentage, or relative, to the maximum dry unit weight is one of the key components in evaluating the state of compactness of a given soil mass that is either naturally occurring or is constructed (fill).
5.2 Soil placed as an engineered fill is compacted to a dense state to obtain satisfactory engineering properties such as shear strength, compressibility, permeability, or combinations thereof. Also, foundation soils are often compacted to improve their engineering properties. Laboratory compaction tests provide the basis for determining the percent compaction and water content needed at the time of compaction to achieve the required engineering properties, and for controlling construction to ensure that the required unit weights and water contents are achieved.
5.3 It is generally recognized that percent compaction is a good indicator of the state of compactness of a given soil mass. However, the engineering properties, such as strength, compressibility, and permeability of a given soil, compacted by various methods to a given state of compactness can vary considerably. Therefore, considerable engineering judgment must be used in relating the engineering properties of soil to the state of compactness.
5.4 Experience indicates that the construction control aspects discussed in 5.2 are extremely difficult to implement or yield erroneous results when dealing with certain soils. Subsections 5.4.1, 5.4.2, and 5.4.3 describe typical problem soils, the problems encountered when dealing with such soils, and possible solutions to these problems.
5.4.1.1 One method to design and control the compaction of such soils is to use a test fill to determine the required degree of compaction and the method to obtain that compaction, followed by the use of a method specification to control the compaction. Components of a method specification typically contain the type and size of compaction equipment to be used, the lift thickness, and the number of passes of the compaction equipment that each lift is subjected to.
Note 3: Success in executing the compaction control of an earthwork project, especially when a method specification is used, is highly dependent upon the quality and experience of the “contractor” and “inspector.”
5.5 An absolute maximum dry unit weight is not necessarily obtained by these test methods.
Note 4: The quality of the result produced by this standard is dependent on the competence of the personnel performing it and the suitability of the equipment and facility used. Agencies that meet the criteria of Practice D3740 are generally considered capable of competent and objective testing/sampling/inspection. Reliable results depend on many factors; Practice D3740 provides a means of evaluating some, but not all, of those factors.
Failed to load document history.
| Publish Date | Document Id | Type | View |
|---|