ASTM D8669-26

Current Revision
Standard Test Method for Lateral Water Migration Resistance Between a Pre-Applied (Blindside) Waterproofing Membrane and Cast-In-Place Concrete

Best Price Guarantee Oct 15, 2026 English 4 Pages

Sub Total (1 Item(s)) $ 0.00
Estimated Shipping $ 0.00
Total (Pre-Tax) $ 0.00

You own the digital copy of this edition

View in Library
or
ASTM International Logo

ASTM D8669-26

Standard Test Method for Lateral Water Migration Resistance Between a Pre-Applied (Blindside) Waterproofing Membrane and Cast-In-Place Concrete

PUBLISH DATE 2026
PAGES 4
ASTM D8669-26

1.1 This test method measures the lateral water migration resistance between a pre-applied (blindside) waterproofing membrane and cast-in-place concrete under controlled laboratory conditions. This test method is suitable for waterproofing membranes that form a bond to cast-in-place concrete but does not rely on confinement for waterproofing performance.

1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

4.1 This test method is intended to test the lateral water migration resistance at the interface of a pre-applied waterproofing membrane and cured concrete, and can be used to compare the lateral resistance performance of pre-applied waterproofing membranes under hydrostatic pressure.

4.2 This test method does not address all conditions that may be encountered in a blindside waterproofing application such as pneumatically applied concrete (i.e., shotcrete), earth retention systems, including tiebacks, rakers, diagonal braces, utility penetrations, formwork ties, etc., which can affect the waterproofing continuity.

4.3 The results obtained in this test method are achieved in a laboratory environment. This test method is useful to compare systems tested to the specific conditions of this standard. It is not possible to establish a precise correlation between laboratory tests on blindside waterproofing membranes and performance attributes after field installation due to variations in concrete mix designs, chemicals in the soil, design, material, and installation.