Standard Test Method for Recovered Carbon Black – Bound Agglomerate Size Analysis of Milled Recovered Carbon Black by Laser Diffraction
1.1 This test method covers the determination of a sphere-equivalent particle size distribution for recovered carbon black (rCB) bound agglomerates via light scattering of a dry powder sample. The method is applicable for the characterization of powders produced from a dry milling process of raw rCB and is recommended for use with materials that have an expected bound agglomerate diameter range of 1 µm to 125 µm.
1.2 This test method uses previously calibrated, manual, or computer-assisted laser diffraction instrumentation.
1.3 Values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
5.1 This method is intended to provide information concerning the bound agglomerate size distribution of rCB powders following a raw rCB milling process. The bound agglomerate size of rCB is known to influence end-use application performance.
5.2 The volume-weighted 97% cumulative undersize diameter, D97, is sensitive to over-sized (under-milled) particles and is of special significance because it is known to be correlated to application performance. D97 is therefore a useful parameter for controlling rCB milling processes.
5.3 Due to the presence of fine particles much less than 10 to 20 µm in diameter and the strong optical absorption of rCB fused agglomerates, Mie Scattering Theory shall be used instead of Fraunhofer Scattering Theory. Mie Scattering Theory requires knowledge or assumption of the wavelength-dependent real and imaginary components of the complex dielectric function. The real component is the refractive index, and the imaginary component is the extinction coefficient, commonly expressed as an absorption index.
Commercial laser diffraction instruments generally use red or infrared laser light for dry dispersion measurements, and despite small possible differences in laser wavelength and composition of rCB sample materials, this standard assumes refractive index of 1.85 and absorption index of 0.84 for all cases. Refractive index and absorption index are both unitless.
5.4 Producers and users of rCB should be aware that results obtained by this method should be used for relative comparison of size distributions and should not be considered absolute. Besides any error from necessary assumptions of particles’ spherical shape and Mie scattering theory, result variation between laser diffraction instrument models is a common observance due to differences in instrument design.
Different laser diffraction instrument models may therefore yield different particle size distributions.
Failed to load document history.
| Publish Date | Document Id | Type | View |
|---|