ASTM E1315-93(2002)

Withdrawn Revision
Standard Practice for Ultrasonic Examination of Steel with Convex Cylindrically Curved Entry Surfaces (Withdrawn 2007)

Best Price Guarantee Sep 15, 1993 English 4 Pages

Sub Total (1 Item(s)) $ 0.00
Estimated Shipping $ 0.00
Total (Pre-Tax) $ 0.00

You own the digital copy of this edition

View in Library
or
ASTM E1315-93(2002) PDF Preview
ASTM E1315-93(2002)

1.1 This practice describes the selection of single-element hard-face ultrasonic search units for which flat-entry-surface reference blocks can be used for examination of steel with convex cylindrically curved entry surfaces.

1.2 The scope of this practice includes the determination of search unit characteristics and radius of surface curvature of the material for which no gain correction is required, or, if a larger search unit is used, the computation of the additional gain required to allow standardization with a flat reference block and examination on a curved surface.

1.3 This practice is intended for use during contact examination of convexly curved steel material using round flat face, piezoelectric search units for longitudinal ultrasonic wave generation in the frequency range from 1 to 10 MHz.

1.4 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

1.1 This practice describes the selection of single-element hard-face ultrasonic search units for which flat-entry-surface reference blocks can be used for examination of steel with convex cylindrically curved entry surfaces.

1.2 The scope of this practice includes the determination of search unit characteristics and radius of surface curvature of the material for which no gain correction is required, or, if a larger search unit is used, the computation of the additional gain required to allow standardization with a flat reference block and examination on a curved surface.

1.3 This practice is intended for use during contact examination of convexly curved steel material using round flat face, piezoelectric search units for longitudinal ultrasonic wave generation in the frequency range from 1 to 10 MHz.

1.4 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.