Standard Test Method for Determining Threshold Stress Intensity Factor for Environment-Assisted Cracking of Metallic Materials
1.1 This test method covers the determination of the environment-assisted cracking threshold stress intensity factor parameters, KIEAC and KEAC, for metallic materials from constant-force testing of fatigue precracked beam or compact fracture specimens and from constant-displacement testing of fatigue precracked bolt-load compact fracture specimens.
1.2 This test method is applicable to environment-assisted cracking in aqueous or other aggressive environments.
1.3 Materials that can be tested by this test method are not limited by thickness or by strength as long as specimens are of sufficient thickness and planar size to meet the size requirements of this test method.
1.4 A range of specimen sizes with proportional planar dimensions is provided, but size may be variable and adjusted for yield strength and applied force. Specimen thickness is a variable independent of planar size.
1.5 Specimen configurations other than those contained in this test method may be used, provided that well-established stress intensity calibrations are available and that specimen dimensions are of sufficient size to meet the size requirements of this test method during testing.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
5.1 The parameters KEAC or KIEAC determined by this test method characterize the resistance to crack growth of a material with a sharp crack in specific environments under loading conditions in which the crack-tip plastic region is small compared with the crack depth and the uncracked ligament.
The less restrictive thickness requirements of KEAC are intended for those conditions in which the results are a strong function of the thickness of the specimen and the application requires the testing of specimens with thickness representative of the application.
Since the chemical and mechanical influences cannot be separated, in some material/environment combinations, the thickness must be treated as a variable.
A KEAC or KIEAC value is believed to represent a characteristic measurement of environment-assisted cracking resistance in a precracked specimen exposed to an environment under sustained tensile loading.
A KEAC or KIEAC value may be used to estimate the relationship between failure stress and defect size for a material under any service condition, where the combination of crack-like defects, sustained tensile loading and the same specific environment would be expected to occur.
(Background information concerning the development of this test method can be found in Refs (3-18).)
5.1.1 The apparent KEAC or KIEAC of a material under a given set of chemical and electrochemical environmental conditions is a function of the test duration.
It is difficult to furnish a rigorous and scientific proof for the existence of a threshold (4, 5). Therefore, application of KEAC or KIEAC data in the design of service components should be made with awareness of the uncertainty inherent in the concept of a true threshold for environment-assisted cracking in metallic materials (6, 18).
A measured KEAC or KIEAC value for a particular combination of material and environment may, in fact, represent an acceptably low rate of crack growth rather than an absolute upper limit for crack stability.
Care should be exercised when service times are substantially longer than test times.
5.1.2 The degree to which force deviations from static tensile stress will influence the apparent KEAC or KIEAC of a material is largely unknown.
Small-amplitude cyclic loading, well below that needed to produce fatigue crack growth, superimposed on sustained tensile loading was observed to significantly lower the apparent threshold for stress corrosion cracking in certain instances (7, 8).
Therefore, caution should be used in applying KEAC or KIEAC data to service situations involving cyclic loading.
In addition, since this standard is for static loading, small-amplitude cyclic loading should be avoided during testing.
5.1.3 In some material/environment combinations, the smaller the specimen, the lower the measured KEAC value, while in other material/environment combinations the measured KIEAC value will be the lowest value (5, 9, 10, 11, 12).
If, for the material/environment combination of interest, it is not known which specimen size will result in the lower measured value, then it is suggested that the use of both specimen sizes should be considered; that is, specimens with thicknesses representative of the application and specimens in which the thickness meets the requirements (see 7.2.1) of a KIEAC value.
5.1.3.1 The user may optionally determine and report a KEAC value or a KIEAC value.
The specimen size validity requirements for a KEAC value meet the size requirements developed for Test Method E647 to achieve predominately elastic behavior in the specimen.
Test Method E647 size requirements for compact specimens should be applied to both the compact specimen and the beam specimen.
The specimen size validity requirements for a KIEAC value meet the size requirements developed for plane strain conditions for Test Method E399.
5.1.4 Evidence of environment-assisted crack growth under conditions that do not meet the validity requirements of 7.2 may provide an important indication of susceptibility to environmental cracking but cannot be used to determine a valid KEAC value (14).
5.1.5 Environment-assisted cracking is influenced by both mechanical and electrochemical driving forces.
The latter can vary with crack depth, opening, or shape and may not be uniquely described by the fracture mechanics stress intensity factor.
As an illustrative example, note the strong decrease reported in KISCC with decreasing crack size below 5 mm for steels in 3 % NaCl in water solution (15).
Geometry effects on K similitude should be experimentally assessed for specific material/environment systems.
Application modeling based on KEAC similitude should be conducted with caution when substantial differences in crack and specimen geometry exist between the specimen and the component.
5.1.6 Not all combinations of material and environment will result in environment-assisted cracking.
In general, susceptibility to aqueous stress-corrosion cracking decreases with decreasing material strength level.
When a material in a certain environment is not susceptible to environment-assisted cracking, it will not be possible to measure KEAC or KIEAC.
This method can serve the following purposes:
Failed to load document history.