Logo
Login Sign Up
Current Revision

ASTM E2513-07(2019)e1

Standard Specification for Multi-Story Building External Evacuation Platform Rescue Systems
Best Price Guarantee
Instant

$99.00

2-5 Days

$99.00

SAVE 10%

$178.20


Sub Total (1 Item(s))

$ 0.00

Estimated Shipping

$ 0.00

Total (Pre-Tax)

$ 0.00


View in Library
or
ASTM International Logo

ASTM E2513-07(2019)e1

Standard Specification for Multi-Story Building External Evacuation Platform Rescue Systems

PUBLISH DATE 2019
PAGES 33
ASTM E2513-07(2019)e1

This specification covers the specifications, safety requirements, performance, design, practices, marking instructions and test methods for multi-story building external evacuation platform rescue systems (PRS) for emergency escape of persons who cannot use the normal means of egress to a safe area and for vertical transport of emergency responders.

This specification is applicable only to PRSs that are permanently installed, designed for multi-cycle and repetitive use, and where descent is controlled to limit speed before arrival at a floor or landing zone.

Conversely, this specification does not cover:

  • Platform devices that are used primarily for purposes other than emergency evacuation and/or access,
  • Helicopters or other flying platforms,
  • A PRS utilizing platforms that can be transported to or between buildings during operations,
  • A PRS using driving methods other than positive drive as drum and ropes.

1.1 This specification covers the specifications, safety requirements, performance, design, practices, marking instructions and test methods for Multi-Story Building External Evacuation Platform Rescue Systems (PRS) for emergency escape of persons who cannot use the normal means of egress to a safe area and for transport of emergency responders vertically.

1.2 This specification is applicable only to PRSs:

  • 1.2.1 Permanently installed;
  • 1.2.2 Designed for multi-cycle and repetitive use; and
  • 1.2.3 Where descent is controlled to limit speed before arrival at a floor or landing zone.

1.3 This specification does not cover:

  • 1.3.1 Platform devices that are used primarily for purposes other than emergency evacuation or access, or both;
  • 1.3.2 Helicopters or other flying platforms;
  • 1.3.3 Any other devices covered under/within ASME A17.1;
  • 1.3.4 A PRS utilizing platform(s) that can be transported to or between buildings during operations; and
  • 1.3.5 A PRS using driving methods other than positive drive as drum and ropes.

1.4 Operation of a PRS is limited to trained and authorized operators.

1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.5.1 Exception— In 5.2.1 and 5.2.2, inch-pound units are provided in parentheses after the SI units for information only.

1.6 Table of Contents:

 

Section

Scope

1

Referenced Documents

2

Terminology

3

Building Interface Requirements and Installation

4

Environmental Conditions

5

Fire and Smoke Protection

6

Material Requirements

7

Structural, Mechanical and Stability Calculations

8

Mechanical and Physical Properties

9

Buffers and Guides

10

Suspension Wire Rope and Wire Rope Connections

11

Hoisting Machines and Pulleys

12

Means to Prevent Falling of the Platform(s)

13

Electrical Power Requirements

14

Operation, Control and Communication

SDO ASTM: ASTM International
Document Number E2513
Publication Date Aug. 1, 2019
Language en - English
Page Count 33
Revision Level 07(2019)e1
Supercedes
Committee E06.77
Loading...

Failed to load document history.

Publish Date Document Id Type View