Standard Practice for Building Energy Performance Assessment for a Building Involved in a Real Estate Transaction
1.1 Purpose— The purpose of this standard is to define a commercially useful practice in the United States of America for conducting a building energy performance assessment (BEPA) on a building involved in a commercial real estate transaction and subsequent reporting of the building energy performance information. The practice is intended to provide a methodology to the user for the collection, compilation, analysis, and reporting of building energy performance information associated with a commercial building.
The practice may be used independently or as a voluntary supplement to Guide E2018 for property condition assessments or Practice E1527 for Phase I environmental site assessments. Utilization of this practice and performance of a BEPA is voluntary. If the property owner (for example, the seller) is unwilling or unable to provide building energy consumption and cost information, a BEPA cannot be performed.
1.2 Building Energy Performance— This practice defines building energy performance as the building’s total annual energy consumption and cost for heating, cooling, electricity, and other related uses.
Energy consumption, for example, includes total electricity purchased; purchased or delivered steam, hot water, or chilled water; natural gas; fuel oil; coal; propane; biomass; or any other matter consumed as fuel and any electricity generated on site from renewable/alternative energy systems (for example, wind energy generator technology, fuel cells, microturbines or solar photovoltaic systems).
1.3 Objectives— Objectives in the development of this practice are to:
1.4 Documentation— The scope of this practice includes data collection, compilation and reporting requirements. Documentation of all sources, records, and resources relied upon in the investigation is provided in the report.
1.5 Considerations Outside the Scope— The use of this practice is limited to the collection, compilation, and analysis of building energy performance information as defined by this practice for real estate transactions in the United States of America.
While this information may be used to facilitate building benchmarking, labeling, rating or ranking, reporting of building energy performance information between a seller and a buyer or a landlord and a tenant on a voluntary basis or as may be required by building benchmarking, labeling, disclosure or mandatory auditing regulations applicable to the building, or any other use, such use is beyond the scope of this practice. This ASTM Standard Practice does not supersede existing statutes and regulations.
1.6 Organization of This Practice— This practice has 13 sections and 11 appendices. The appendices are included for informational purposes only and are not part of the procedures prescribed in this practice.
Section 1 | Describes the scope of the practice. |
Section 2 | Identifies referenced documents. |
Section 3 | Provides terminology pertinent to the practice. |
Section 4 | Discusses the significance and use of the practice. |
Section 5 | Discusses the relationship between this practice and ASTM Guide E2018 or ASTM Practice E1527. |
Section 6 | Describes the user's responsibilities under this practice. |
Section 7 | Describes the BEPA process. |
Section 8 | Describes the site visit and walk-through. |
Section 9 | Discusses interviews with owner , operator, or key site manager. |
Section 10 | Describes records collection for the BEPA process. |
Section 11 | Provides the records analysis methodology for building energy consumption data. |
Section 12 | < |
1.1 Purpose— The purpose of this standard is to define a commercially useful practice in the United States of America for conducting a building energy performance assessment (BEPA) on a building involved in a commercial real estate transaction and subsequent reporting of the building energy performance information. The practice is intended to provide a methodology to the user for the collection, compilation, analysis, and reporting of building energy performance information associated with a commercial building. The practice may be used independently or as a voluntary supplement to Guide E2018 for property condition assessments or Practice E1527 for Phase I environmental site assessments. Utilization of this practice and performance of a BEPA is voluntary. If the property owner (for example, the seller) is unwilling or unable to provide building energy consumption and cost information, a BEPA cannot be performed.
1.2 Building Energy Performance— This practice defines building energy performance as the building’s total annual energy consumption and cost for heating, cooling, electricity, and other related uses. Energy consumption, for example, includes total electricity purchased; purchased or delivered steam, hot water, or chilled water; natural gas; fuel oil; coal; propane; biomass; or any other matter consumed as fuel and any electricity generated on site from renewable/alternative energy systems (for example, wind energy generator technology, fuel cells, microturbines or solar photovoltaic systems).
1.3 Objectives— Objectives in the development of this practice are to:
1.4 Documentation— The scope of this practice includes data collection, compilation and reporting requirements. Documentation of all sources, records, and resources relied upon in the investigation is provided in the report.
1.5 Considerations Outside the Scope— The use of this practice is limited to the collection, compilation, and analysis of building energy performance information as defined by this practice for real estate transactions in the United States of America. While this information may be used to facilitate building benchmarking, labeling, rating or ranking, reporting of building energy performance information between a seller and a buyer or a landlord and a tenant on a voluntary basis or as may be required by building benchmarking, labeling, disclosure or mandatory auditing regulations applicable to the building, or any other use, such use is beyond the scope of this practice. This ASTM Standard Practice does not supersede existing statutes and regulations.
1.6 Organization of This Practice— This practice has 13 sections and 11 appendices. The appendices are included for informational purposes only and are not part of the procedures prescribed in this practice.
Section 1 |
Describes the scope of the practice. |
Section 2 |
Identifies referenced documents. |
Section 3 |
Provides terminology pertinent to the practice. |
Section 4 |
Discusses the significance and use of the practice. |
Section 5 |
Discusses the relationship between this practice and ASTM Guide E2018 or ASTM Practice E1527. |
Section 6 |
Describes the user's responsibilities under this practice. |
Section 7 |
Describes the BEPA process. |
Section 8 |
Describes the site visit and walk-through. |
Section 9 |
Discusses interviews with owner , operator, or key site manager. |
Section 10 |
Describes records collection for the BEPA process. |
Section 11 |
4.1 Uses— This practice is intended for use on a voluntary basis by parties who wish to conduct a BEPA on a building. The process defined in this practice involves the collection of building energy consumption information, some of which may be collected as part of E2018 PCA or E1527 ESA. The practice is intended primarily as an approach to conducting a standardized inquiry designed to identify representative building energy performance in connection with a commercial property involved in a real estate transaction. This practice is intended to reflect a commercially practical and reasonable inquiry.
4.1.1 A number of states including CA, CO, WA and NJ, and more than three dozen cities, county and municipal governments, including Ann Arbor, MI, Atlanta, GA, Austin, TX, Berkeley, CA, Bloomington, MN, Boston, MA, Boulder, CO, Cambridge, MA, Chicago, IL, Chula Vista, CA, Columbus, OH, Denver, CO, Des Moines, IA, Edina, MN, Evanston, IL, Fort Collins, CO, Indianapolis, IN, Kansas City, MO, Los Angeles, CA, Miami, FL, Minneapolis, MN, Montgomery County, MD, New York City, NY, Orlando, FL, Philadelphia, PA, Pittsburgh, PA, Portland, ME, Portland, OR, Reno, NV, Salt Lake City, UT, San Diego, CA, San Francisco, CA, San Jose, CA, Seattle, WA, South Portland, ME, St. Louis, MO, St. Louis Park, MN, St. Paul, MN and Washington, D.C. have building energy performance benchmarking and reporting policies. Users in these locations must comply with applicable ordinances and regulations.
4.2 Clarifications on Use:
4.2.1 Use in Conjunction with E2018 PCA or E1527 ESA— This practice, when added as a supplemental scope of work to a E2018 PCA or a E1527 ESA, is designed to assist the user and consultant in developing information about energy consumption in a building or buildings involved in a real estate transaction. The BEPA also has utility to a wide range of persons, including those who may not be involved in a real estate transaction.
4.2.2 Independent Use— This practice may also be used independently of any other building assessment to determine building energy performance.
4.2.3 Site-Specific— This practice is property-specific in that it relates to existing building energy performance. The practice is not intended to replace E2018 PCA or E1527 ESA conducted by a qualified consultant or individual, but rather to supplement it.
4.3 Who May Conduct— A BEPA shall be performed by a qualified consultant or individual (hereafter referred to as the “Consultant”) with the education, training and experience necessary to perform the requirements of this practice (see Appendix X4). No practical approach can be designed to eliminate the role of professional judgment and the value and need for experience in the individual performing the inquiry. The professional experience of the Consultant is, consequently, important to the performance of this BEPA.
4.4 Additional Services— As set forth in Section 13, additional services may be contracted for between the user and the Consultant. Such additional services may include issues not included within the scope of this practice. For example, the user or Consultant may wish to benchmark the building against similar buildings in the portfolio or in the same geographical area or identify select green building attributes that may contribute to the energy efficiency performance and/or the building’s valuation.
4.4.1 Benchmarking Additional Service— Any benchmarking system selected relies on critical data in generating its output, so the validity of the data collection process directly impacts the integrity and usefulness of the benchmarking system’s results. Utilization of this practice and adoption of its data collection approach can serve to enhance the integrity of the benchmarking process for all transactional stakeholders in a standardized, fully transparent, uniform, and consistent manner. Notwithstanding, building energy consumption information should always be evaluated within the context in which it is collected and building energy consumption numbers should not be used without conveying this context. (Refer to Appendix X1 for additional information.)
4.5 Principles— The following principles are an integral part of this practice and are intended to be referred to in resolving any ambiguity or exercising such discretion as is accorded the user or Consultant in performing a BEPA.
4.6 Rules of Engagement— The contractual and legal obligations between a Consultant and a user (and other parties, if any) are outside the scope of this practice. No specific legal relationship between the Consultant and user was considered during the preparation of this practice.