1.1 These test methods cover the chemical analysis of ferromanganese having chemical compositions within the following limits:

ElementConcentration, %
Arsenic0.30 max
Carbon7.50 max
Chromium0.50 max
Lead0.050 max
Manganese16.0 to 90.0
Phosphorus0.35 max
Silicon7.00 max
Sulfur0.050 max
Tin0.020 max

1.2 The test methods in this standard are contained in the sections indicated below:

Sections
Arsenic by the Molybdenum Blue Photometric Method (0.002 to 0.06 %)
Lead by the Dithizone Photometric Method (0.004 to 0.01 %)

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Section 5 and in special warning paragraphs throughout.

1.1 These test methods cover the chemical analysis of ferromanganese having chemical compositions within the following limits:

ElementConcentration, %
Arsenic0.30 max
Carbon7.50 max
Chromium0.50 max
Lead0.050 max
Manganese16.0 to 90.0
Phosphorus0.35 max
Silicon7.00 max
Sulfur0.050 max
Tin0.020 max

1.2 The test methods in this standard are contained in the sections indicated below:

Sections
Arsenic by the Molybdenum Blue Photometric Method (0.002 to 0.06 %)
Lead by the Dithizone Photometric Method (0.004 to 0.01 %)

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.