BSI BS 1881-207:1992

Testing concrete -- Recommendations for the assessment of concrete strength by near-to-surface tests

PUBLISH DATE 1992
PAGES 20
BSI BS 1881-207:1992

This Part of BS 1881 gives recommendations on tests that are designed to assess the strength of concrete by causing localized failure in a small zone, typically up to 75 mm from the surface, according to the method. The recommendations cover the following test methods:

  1. internal fracture;

  2. pull-out;

  3. pull-off;

  4. penetration resistance;

  5. break-off.

NOTE The titles of publications referred to in this standard are listed on the inside back cover.

Procedures for internal fracture, pull-out, pull-off, penetration resistance, break-off tests and use of results.