Domestic lighting appliances for use with liquefied petroleum gases

Best Price Guarantee Mar 31, 1958 English 24 Pages

Sub Total (1 Item(s)) $ 0.00
Estimated Shipping $ 0.00
Total (Pre-Tax) $ 0.00

You own the digital copy of this edition

View in Library
or
British Standards Institution Logo

BSI BS 2977:1958

Domestic lighting appliances for use with liquefied petroleum gases

PUBLISH DATE 1958
PAGES 24
BSI BS 2977:1958

1. This British Standard specifies the classification, construction, operation, safety requirements and tests for lighting appliances intended for domestic use with butane gas at 11 in. w.g. pressure.

NOTE 1. This gas is a mixture consisting predominantly of C4 hydrocarbons with some Ca hydrocarbons and small amounts of C5 hydrocarbons. However, the distributors of the gas are able to supply gas whose combustion characteristics are always within the limits prescribed by the test gases defined in Clause 29.

NOTE 2. The term ‘Lighting appliances’ includes their component parts, e.g. burners, brackets, pendants and their taps.

Specifies classification, construction, operation, safety requirements and tests for lighting appliances intended for domestic use with commercial butane at 11 in w.g. pressure, and commercial propane at 14 in w.g. pressure.