Measurement of airborne noise from hydraulic fluid power systems and components -- Simplified method of determining sound power levels from pumps using an anechoic chamber
This Part of BS 5944 describes procedures for the determination of the sound power levels of a hydraulic fluid power pump, under controlled conditions of installation and operation, suitable for providing a basis for comparing the noise levels of pumps in terms of:
From these sound power levels, sound pressure levels may be calculated for reporting purposes (see clause 11).
For general purposes, the frequency range of interest includes the octave bands with centre frequencies between 125 Hz and 8 000 Hz.
This method is applicable to all types of hydraulic fluid power pumps operating under steady-state conditions, irrespective of size, except for any limitations imposed by the size of the test environment (see clause 4).
NOTE The titles of the publications referred to in this standard are listed on the inside back cover.
Describes simplified procedures for the determination of the sound power levels of a hydraulic fluid power pump under controlled conditions of installation and operation using a quadrispherical microphone array in an anechoic chamber.
These procedures provide a basis for comparing noise levels of pumps.
Failed to load document history.