BSI BS 6200-3.28.3:1995

Withdrawn Revision
Sampling and analysis of iron, steel and other ferrous metals. Methods of analysis. Determination of sulphur -- Steel and iron: spectrophotometric method

Best Price Guarantee Dec 15, 1995 English 16 Pages

This Document Has Been Superseded

A newer publication replaces it: BSI BS ISO 10701


Sub Total (1 Item(s)) $ 0.00
Estimated Shipping $ 0.00
Total (Pre-Tax) $ 0.00

You own the digital copy of this edition

View in Library
or
British Standards Institution Logo

BSI BS 6200-3.28.3:1995

Sampling and analysis of iron, steel and other ferrous metals. Methods of analysis. Determination of sulphur -- Steel and iron: spectrophotometric method

PUBLISH DATE 1995
PAGES 16
BSI BS 6200-3.28.3:1995

This International Standard specifies a methylene blue spectrophotometric method for the determination of sulfur in steel and iron.

The method is applicable to sulfur contents between 0,000 3 % (m/m) and 0,010 % (m/m). However, niobium, silicon, tantalum and titanium interfere in the determination of sulfur.

Depending on the concentration of the interfering elements, the application ranges and test portion masses given in Table 1 apply.

Table 1

Maximum allowable content of the interfering elements Test portion Application ranges Δws
% (m/m) % (m/m)
Nb Si Ta Ti g
0,5 1,0 0,3 1,0 1,0 0,000 3 to 0,001 0
1,0 2,0 0,6 2,0 0,50 0,001 0 to 0,010

Applicable to **sulphur content** of between 0.0003% (m/m) and 0.010% (m/m) depending upon the niobium, silicon, tantalum and titanium content.

Loading...

Failed to load document history.

Publish Date Document Id Type View