Eurocode 3 - Design of steel structures -- Towers, masts and chimneys
1.1 Scope of FprEN 1993-3
(1) This document provides rules for structural design of towers, masts and chimney structures, that fall into any of the following classifications, with the exceptions given in (3), (4) and (5).
(2) This document is applicable to:
NOTE 1 The structures are mainly exposed to wind loading.
NOTE 2 For overhead transmission line towers, see also the EN 50341 series.
(3) This document does not apply to:
(4) This document does not cover special provisions for seismic design, which are given in the EN 1998 series.
(5) Special measures that might be necessary to limit the consequences of accidents are not covered in this document. For resistance to fire, see EN 1993-1-2.
(6) Provisions for the guys of guyed structures are given in EN 1993-1-11 and supplemented in this document.
(7) For provisions concerning aspects such as chemical attack, thermo-dynamical performance or thermal insulation of chimneys, see EN 13084-1. For the design of liners, see EN 13084-6.
NOTE 1 Foundations are covered in the EN 1997 series. See also EN 13084-1.
NOTE 2 Wind loads and procedures for the wind response of structures are specified in EN 1991-1-4.
1.2 Assumptions
(1) Unless specifically stated, EN 1990, EN 1991 (all parts) and EN 1993 1 (all parts) apply.
(2) The design methods given in this document are applicable if:
NOTE Execution is covered in this document to the extent that is necessary to indicate the quality of the construction materials and products and the standard of workmanship on site needed to comply with the assumptions of the design rules.