BSI BS EN 60079-15:2010

Current Consolidated
Explosive atmospheres -- Equipment protection by type of protection 'n'

Best Price Guarantee Nov 30, 2016 English 84 Pages

This Document Has Been Superseded

A newer publication replaces it: BSI BS EN 60079-7, BSI BS EN IEC 60079-15


Sub Total (1 Item(s)) $ 0.00
Estimated Shipping $ 0.00
Total (Pre-Tax) $ 0.00

You own the digital copy of this edition

View in Library
or
British Standards Institution Logo

BSI BS EN 60079-15:2010

Explosive atmospheres -- Equipment protection by type of protection 'n'

PUBLISH DATE 2016
PAGES 84
BSI BS EN 60079-15:2010

This part of IEC 60079 specifies requirements for the construction, testing and marking for Group II electrical equipment with type of protection, 'n' intended for use in explosive gas atmospheres. This standard applies to electrical equipment where the rated voltage does not exceed 15 kV r.m.s. a.c. or d.c.

This part of IEC 60079 is applicable to non-sparking electrical equipment and also to electrical equipment with parts or circuits producing arcs or sparks or having hot surfaces which, if not protected in one of the ways specified in this standard, could be capable of igniting a surrounding explosive gas atmosphere. This standard describes several different methods by which this can be achieved which may be combined with other methods described in IEC 60079‑0 .

This standard supplements and modifies the general requirements of IEC 60079‑0 , except as indicated in Table 1. Where a requirement of this standard conflicts with a requirement of IEC 60079‑0 , the requirement of this standard takes precedence.

Table 1
Relationship of this part to IEC 60079-0
Clause of IEC 60079‑0 IEC 60079‑0 clause application to IEC 60079‑15
Ed. 5.0 (2007)

(informative)

Ed. 6.0 1 (future edition)

(informative)

Clause / Subclause title

(normative)

Protected spar king Non sparking Restricted breathing
nC nA nR
4 4 Equipment grouping Applies Applies Applies
4.1 4.1 Group I Excluded Excluded Excluded
4.2 4.2 Group II Applies Applies Applies
4.3 4.3 Group III Excluded Excluded Excluded
4.4 4.4 Equipment for a particular explosive atmosphere Applies Applies Applies
5.1 5.1 Environmental influences Applies Applies Applies
5.1.1 5.1.1 Ambient temperature Applies Applies Applies
5.1.2 5.1.2 External source of heating or cooling Applies Applies Applies
5.2 5.2 Service temperature Applies Applies Applies
5.3.1 5.3.1 Determination of maximum surface temperature Applies Applies Applies
5.3.2.1 5.3.2.1 Group I electrical equipment Excluded Excluded Excluded
Loading...