Safety of transformers, reactors, power supply units and combinations thereof -- Particular requirements and tests for isolating transformers for medical IT systems for the supply of medical locations

Best Price Guarantee May 20, 2025 English 26 Pages


Sub Total (1 Item(s)) $ 0.00
Estimated Shipping $ 0.00
Total (Pre-Tax) $ 0.00

You own the digital copy of this edition

View in Library
or
British Standards Institution Logo

BSI BS EN IEC 61558-2-15:2025

Safety of transformers, reactors, power supply units and combinations thereof -- Particular requirements and tests for isolating transformers for medical IT systems for the supply of medical locations

PUBLISH DATE 2025
PAGES 26
BSI BS EN IEC 61558-2-15:2025

This part of IEC 61558 deals with safety of isolating transformers for medical IT systems for the supply of medical locations. NOTE 1 Safety includes electrical, thermal and mechanical aspects. Unless otherwise specified, from here onward, the term transformer covers isolating transformers for medical IT systems for the supply of medical locations.

This document is applicable to isolating transformers, single-phase or three-phase, air-cooled (natural or forced) dry-type transformers for the supply of medical IT system for group 2 medical locations, designed to be permanently connected to the fixed wiring and intended to form the medical IT system on the secondary side. The windings can be encapsulated or non encapsulated. NOTE 2 IT systems are defined in IEC 60364-1. The installation rules for medical IT system for group 2 medical locations are covered by IEC 60364-7-710.

Transformers covered by this document are intended for medical IT systems for the supply of medical locations. All other transformers or equipment connected downstream from the transformer are not covered by this document.

The rated supply voltage does not exceed 1 000 V AC. The rated supply frequency and internal operational frequency do not exceed 500 Hz. The rated output does not be less than 0.5 kVA and does not exceed 10 kVA for single-phase and three-phase transformers for medical IT system for group 2 medical locations.

This document may be applicable to isolating transformers intended to supply other medical installations that are not group 2 medical locations without limitation of the rated output subject to an agreement between the purchaser and the manufacturer. NOTE 3 Transformers intended to supply distribution networks other than medical IT systems are not included in the scope.

The no-load output voltage and the rated output voltage does not exceed 250 V AC for single-phase or three-phase transformer (phase-to-phase voltage).

This document does not cover power supply units and is not intended to be used in conjunction with IEC 61558-2-16 for switch mode power supply units. This document is not applicable to external circuits and their components intended to be connected to the input terminals and output terminals of the transformers.

Transformers covered by this document are used in applications where double or reinforced insulation between circuits is required by the installation rules or by the appliance specification. NOTE National installation rules of some countries have different or additional requirements listed in Annex C of IEC 60364-7-710:2021.

Attention is drawn to the following:

  • for transformers intended to be used in vehicles, on board ships, and aircraft, additional requirements (from other applicable standards, national rules, etc.);
  • measures to protect the enclosure and the components inside the enclosure against external influences such as fungus, vermin, termites, solar-radiation, and icing;
  • the different conditions for transportation, storage, and operation of the transformers;
  • additional requirements in accordance with other appropriate standards and national rules may be applicable to transformers intended for use in special environments.

This GROUP SAFETY PUBLICATION focusing on SAFETY guidance is primarily intended to be used as a PRODUCT SAFETY STANDARD for the products mentioned in the scope, but is also intended to be used by TCs in the preparation of publications for products similar to those mentioned in the scope of this GROUP SAFETY PUBLICATION, in accordance with the principles laid down in IEC Guide 104 and ISO/IEC Guide 51.

One of the RESPONSIBILITIES of a TC is, wherever applicable, to make use of BSPs and/or GSPs in the preparation of its publications.