Stationary source emissions. Determination of gas and particle-phase polycyclic aromatic hydrocarbons -- Sample preparation, clean-up and determination
This part of ISO 11338 specifies procedures for sample preparation, clean-up and analysis for the determination of gas and particle-phase polycyclic aromatic hydrocarbons (PAH) in stack and waste gases. The analytical methods are capable of detecting sub-microgram concentrations of PAH per cubic metre of sample, depending on the type of PAH and the flue gas volume sampled.
The methods described in this part of ISO 11338 are based on either high performance liquid chromatography (HPLC) or gas chromatography-mass spectrometry (GC-MS).
NOTE ISO 11338-1 describes three methods and specifies minimum requirements for the sampling of PAH in stack and waste gases.
| SDO | BSI: British Standards Institution |
| Document Number | ISO 11338-2 |
| Publication Date | Nov. 27, 2003 |
| Language | en - English |
| Page Count | 32 |
| Revision Level | |
| Supercedes | |
| Committee | EH/2/1 |