BSI BS ISO 5660-1:2015+A1:2019

Current Consolidated
Reaction-to-fire tests. Heat release, smoke production and mass loss rate -- Heat release rate (cone calorimeter method) and smoke production rate (dynamic measurement)

Best Price Guarantee Feb 2, 2021 English 64 Pages

Sub Total (1 Item(s)) $ 0.00
Estimated Shipping $ 0.00
Total (Pre-Tax) $ 0.00

You own the digital copy of this edition

View in Library
or
British Standards Institution Logo

BSI BS ISO 5660-1:2015+A1:2019

Reaction-to-fire tests. Heat release, smoke production and mass loss rate -- Heat release rate (cone calorimeter method) and smoke production rate (dynamic measurement)

PUBLISH DATE 2021
PAGES 64
BSI BS ISO 5660-1:2015+A1:2019

This part of ISOΒ 5660 specifies a method for assessing the heat release rate and dynamic smoke production rate of specimens exposed in the horizontal orientation to controlled levels of irradiance with an external igniter. The heat release rate is determined by measurement of the oxygen consumption derived from the oxygen concentration and the flow rate in the combustion product stream.

The time to ignition (sustained flaming) is also measured in this test.

The dynamic smoke production rate is calculated from measurement of the attenuation of a laser light beam by the combustion product stream.

Smoke obscuration is recorded for the entire test, regardless of whether the specimen is flaming or not.