BSI BS ISO 9096:2017

Current Revision
Stationary source emissions. Manual determination of mass concentration of particulate matter

Best Price Guarantee Sep 19, 2017 English 52 Pages

Sub Total (1 Item(s)) $ 0.00
Estimated Shipping $ 0.00
Total (Pre-Tax) $ 0.00

You own the digital copy of this edition

View in Library
or
British Standards Institution Logo

BSI BS ISO 9096:2017

Stationary source emissions. Manual determination of mass concentration of particulate matter

PUBLISH DATE 2017
PAGES 52
BSI BS ISO 9096:2017

This document describes a reference method for the measurement of particulate matter (dust) concentration in waste gases of concentrations from 20 mg/m3 to 1 000 mg/m3 under standard conditions.

This document is applicable to the calibration of automated monitoring systems (AMS). If the emission gas contains unstable, reactive or semi-volatile substances, the measurement will depend on the filtration temperature.

In-stack methods can be more applicable than out-stack methods for the calibration of automated monitoring systems.