Selection and installation of backflow preventers/Maintenance and field testing of backflow preventers, Includes Update No. 1 (2026)
This volume contains the eighth edition of CSA B64.10, Selection and installation of backflow preventers , and the fifth edition of CSA B64.10.1, Maintenance and field testing of backflow preventers . CSA B64.10 supersedes the previous editions published in 2017, 2011, 2007, 2001, 1994, 1988 (as part of the CAN/CSA-B64 Series), and 1981. CSA B64.10.1 supersedes the previous editions published in 2017, 2011, 2007, and 2001. This edition includes the following major changes
The Standards provide information on other methods of preventing contamination of potable water by backflow from back siphonage or back pressure. These Standards provide selection criteria, installation, and maintenance procedures, and techniques that represent the general state of the art, but should not be construed as all-inclusive, especially where procedures and techniques are altered to meet special conditions. Where there are problems with a specific installation, it is suggested that the manufacturer of the backflow preventer be consulted. These Standards were prepared by the Technical Committee on Backflow Preventers and Water Pressure Reducing Valves, under the jurisdiction of the Strategic Steering Committee on Construction and Civil Infrastructure, and have been formally approved by the Technical Committee. These Standards have been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. They have been published as National Standards of Canada by CSA Group. ------------------------------------------------------------------------------------------------------------------------------------------ CSA B64.10:23 - Selection and installation of backflow preventers Scope 1.1 Application This Standard specifies requirements for the selection and installation of backflow preventers. Additional information on how backflow due to back siphonage and back pressure occurs, and how to select and apply specific devices, is included in Annexes A, B, and C
This Standard does not cover
This Standard does not specify requirements for maintenance or field testing after the initial installation. Such requirements are specified in CSA B64.10.1.
In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. -----------------------------------------------------------------------------------------------------------------------------------------
This Standard does not specify requirements for the selection and installation of backflow preventers. Such requirements are specified in CSA B64.10.
In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
This Standard is written in SI (metric) units. For conversion tables, see Annex D of CSA B64.10. Vacuum is expressed in pressure below ambient.
Failed to load document history.
| Publish Date | Document Id | Type | View |
|---|