Logo
Login Sign Up
Current Revision

IEC 60404-14 Ed. 1.0 b:2002

Magnetic materials - Part 14: Methods of measurement of the magnetic dipole moment of a ferromagnetic material specimen by the withdrawal or rotation method
Best Price Guarantee
Instant

$131.00

2-5 Days

$131.00

SAVE 10%

$235.80


Sub Total (1 Item(s))

$ 0.00

Estimated Shipping

$ 0.00

Total (Pre-Tax)

$ 0.00


or
International Electrotechnical Commission Logo

IEC 60404-14 Ed. 1.0 b:2002

Magnetic materials - Part 14: Methods of measurement of the magnetic dipole moment of a ferromagnetic material specimen by the withdrawal or rotation method

PUBLISH DATE 2002
PAGES 36
IEC 60404-14 Ed. 1.0 b:2002
Magnetic materials - Part 14: Methods of measurement of the magnetic dipole moment of a ferromagnetic material specimen by the withdrawal or rotation method
Applicable to all ferromagnetic materials. It is particularly aimed at the measurement of the magnetic dipole moment of permanent magnet (magnetically hard) materials and the measurement of the specific saturation magnetic polarization of cemented carbide materials having a ferromagnetic binder. To describe the general principles of the determination of the magnetic dipole moment of a ferromagnetic material specimen using a detection coil in an open magnetic circuit. By including a means of magnetizing the material to saturation, the saturation magnetic dipole moment can also be determined. In addition, the average magnetic polarization of a test specimen can be derived from the measurement of its magnetic dipole moment and volume. The calibration of magnetic moment coil systems and the measurement of the magnetic dipole moment of feebly magnetic materials can also be determined using this method. Measurements are normally performed at room temperature but measurements at other temperatures can be conducted by heating or cooling the volume occupied by the test specimen within the detection coil. The measurement of remanence, coercivity, maximum energy product and other parameters can be made in a closed magnetic circuit as described in IEC 60404-4 and IEC 60404-5. Measurement of the coercivity HcJ of soft and semi-hard materials can also be performed in an open circuit as described in IEC 60404-7.
SDO IEC: International Electrotechnical Commission
Document Number IEC 60404
Publication Date June 1, 2002
Language b - English & French
Page Count 36
Revision Level 1.0
Supercedes
Committee 68
Publish Date Document Id Type View
June 1, 2002 IEC 60404-14 Ed. 1.0 b:2002 Revision
June 1, 2002 Revision