IEC 61526 Ed. 4.0 b:2024

Radiation protection instrumentation - Measurement of personal dose equivalents for X, gamma, neutron and beta radiations - Active personal dosemeters

PUBLISH DATE 2024
PAGES 170
IEC 61526 Ed. 4.0 b:2024
Radiation protection instrumentation - Measurement of personal dose equivalents for X, gamma, neutron and beta radiations - Active personal dosemeters
IEC 61526:2024 applies to personal dosemeters with the following characteristics:
a) They are worn on the trunk, close to the eye, or on the extremities.
b) They measure the personal dose equivalents Hp(10), Hp(3), and Hp(0,07), from external X and gamma, neutron (not for Hp(3)), and beta radiations, and may measure the respective personal dose equivalent rates for the same radiations (for alarming purposes).
c) They have a digital indication. This indication may or may not be attached.
d) They have alarm functions for the personal dose equivalents or personal dose equivalent rates except for hybrid dosemeters. For hybrid dosemeters an alarm function for the personal dose equivalents shall be implemented in the associated readout system.
This document specifies requirements for the dosemeter and, if supplied, for its associated readout system.
This document specifies, for the dosemeters described above, general characteristics, general test procedures, radiation characteristics as well as electrical, mechanical, safety and envi­ronmental characteristics.
This edition includes the following significant technical changes with respect to the previous edition:
a) Modification of the title;
b) Inclusion of the measurement quantity for the dose in the lens of the eye, Hp(3);
c) Inclusion of measurement quantity for dose in the skin and extremities, Hp(0,07);
d) Inclusion of dosemeters between active and passive: "hybrid dosemeters";
e) Inclusion of software requirements;
f) Harmonization of requirements for linearity to IEC 62387;
g) Revised neutron energy response requirements.
SDO IEC: International Electrotechnical Commission
Document Number IEC 61526
Publication Date March 1, 2024
Language b - English & French
Page Count 170
Revision Level 4.0
Supercedes
Committee 45B
Publish Date Document Id Type View
March 1, 2024 Revision
March 1, 2024 IEC 61526 Ed. 4.0 b:2024 Revision
July 1, 2010 IEC 61526 Ed. 3.0 b:2010 Revision