Safety of machinery - Electro-sensitive protective equipment - Part 4-3: Particular requirements for equipment using vision based protective devices (VBPD) - Additional requirements when using stereo vision techniques (VBPDST)
Safety of machinery - Electro-sensitive protective equipment - Part 4-3: Particular requirements for equipment using vision based protective devices (VBPD).
Additional requirements when using stereo vision techniques (VBPDST).
IEC TS 61496-4-3:2022 is available as IEC TS 61496-4-3:2022 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC TS 61496-4-3:2022 specifies requirements for the design, construction and testing of non-contact electro-sensitive protective equipment (ESPE) designed specifically to detect persons or parts of persons as part of a safety-related system, employing vision-based protective devices (VBPDs) using stereo vision techniques (VBPDST) for the sensing function.
Special attention is directed to features which ensure that an appropriate safety-related performance is achieved. An ESPE can include optional safety-related functions, the requirements for which are given in Annex A of IEC 61496-1:2020 and this document.
Where this document does not contain all necessary provisions, IEC TS 62998-1 applies. It is also possible, for those aspects not considered in this document, to use provisions from IEC TS 62998-1 additionally.
This document does not specify the dimensions or configurations of the detection zone and its disposition in relation to hazardous parts for any particular application, nor what constitutes a hazardous state of any machine. It is restricted to the functioning of the ESPE and how it interfaces with the machine.
The detection principle is based on the evaluation of images from different viewing points (stereoscopic view) for the determination of distance information. This distance information is used to determine the position of an object(s).
Additional requirements and tests can apply in the following cases:
This document is relevant for VBPDSTs having a stated detection capability up to 200 mm. This document can be relevant to applications other than those for the protection of persons or parts of persons like arm or fingers (in the range 14 mm to 200 mm), for example the protection of machinery or products from mechanical damage.
In those applications, additional requirements can be necessary, for example when the materials that are to be recognized by the sensing function have different properties from those of persons. This document does not deal with EMC emission requirements.
IEC TS 61496-4-3:2022 cancels and replaces the first edition published in 2015-05. This edition constitutes a technical revision.
This edition includes the following technical changes with respect to the previous edition: