Logo
Login Sign Up
Current Revision

IEEE 1043-2025

IEEE Recommended Practice for Voltage-Endurance Testing of Form-Wound Bars and Coils
Best Price Guarantee
Instant

$60.00

2-5 Days

$75.00

SAVE 10%

$121.50


Sub Total (1 Item(s))

$ 0.00

Estimated Shipping

$ 0.00

Total (Pre-Tax)

$ 0.00


View in Library
or
Institute of Electrical and Electronics Engineers Logo

IEEE 1043-2025

IEEE Recommended Practice for Voltage-Endurance Testing of Form-Wound Bars and Coils

PUBLISH DATE 2026
PAGES 27
IEEE 1043-2025

A comprehensive framework for the voltage-endurance testing of form-wound bars and coils used in large rotating machine stator windings is provided in this recommended practice.

The procedures for conducting voltage endurance tests on bars/coils with nominal voltage up to 30 000 V, and operating frequencies of 50 Hz or 60 Hz, are outlined.

Power supply and voltage requirements, test set-up, specimen preparation, pre-test evaluation methods, as well as temperature and voltage application and measurement methods are specified.

Guidelines for failure investigations, suggested test records, and test report requirements are provided.

This recommended practice covers the voltage endurance testing of form-wound bars and coils for use in large rotating machine stator windings. Such testing is defined for machines with a nominal voltage rating up to 30 000 V.

These tests are to be applied at 50 Hz or 60 Hz and may be done at either room temperature or elevated temperature. Testing at 50 Hz or 60 Hz may yield different times to failure for comparable samples.

The specimen to be tested should be representative of the bars or coils used in the machine and should include the complete insulated bar and external grading construction that the machine winding would have.

Special features different than those used in the machine should not be added to the test specimens.

The purpose of this recommended practice is to define a voltage endurance test method for use on insulated, form-wound bars and coils for installation in large rotating machine stators.

These voltage endurance tests may be applied to representative specimens of form-wound, insulated bars and coils for either new machines or machines to be rewound.

The intent of this document is to define the specimen, the associated testing equipment, and the procedure for performing these voltage endurance tests.

Specific numerical values for acceptable voltage endurance lifetimes are not recommended in this document. The voltage and temperature of the test, the minimum acceptable lifetime, and the number of specimens to be tested should be established prior to testing (see 7.5).